Browse all practice questions for the Edelmen's Sonography Principles and Instrumentation (SPI) Practice Exam. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

Edelmen's Sonography Principles and Instrumentation (SPI) Practice Exam course image
More practice questions

These questions are part of the practice quiz. Start practicing

  • Which unit is typically used to express Doppler frequency shifts?
  • If a system is not displaying clear images in the far field, this may indicate a problem with which component?
  • Which of the following is not a beam steering technique for a mechanical scan head?
  • Which statement describes an exception about in-vitro bioeffects?
  • Which factor has the greatest influence on the pulse repetition period?
  • Circumferences may be measured in which unit?
  • Which action is not typically performed by the sonographer?
  • For depth calibration accuracy in a test phantom, which properties are most relevant?
  • If the power of a sound wave is increased by a factor of 8, how many decibels is this?
  • To represent 16 shades of grey with minimum bits, how many bits are needed?
  • ______ is the distance covered by one cycle.
  • Which factor most directly determines axial resolution?
  • What is the effect of using a higher frequency on attenuation and imaging depth?
  • The beam diameter at the focus is one-half the transducer diameter.
  • What measures the output of a transducer?
  • In depth calibration testing with a phantom, depth accuracy is most influenced by which property pair?
  • The gray-scale variation in a pulsed-wave Doppler spectrum primarily represents what?
  • In Doppler ultrasound, which incident angle results in no frequency shift?
  • In ultrasound, which region is where the beam is narrowest?
  • The digital scan converter has a number of pixels assigned to each bit.
  • Which term describes the time between the start of one pulse and the start of the next pulse?
  • What unit is commonly used to express an intensity ratio in ultrasound?
  • Which resolution is determined by the spatial pulse length?
  • The region immediately beyond the near field is the far zone.
  • Which statement about Doppler shifts is correct?
  • What is another name for longitudinal resolution?
  • What is the most typical Doppler shift measured clinically?
  • Destructive interference occurs when waves are
  • What determines the frequency of a sound beam from a pulsed transducer?
  • Which artifact is NOT a cause of filling in an anechoic structure such as a cyst?
  • If the beam area is doubled while intensity remains unchanged, power will
  • If the number of scan lines per frame is increased, what happens to frame rate?
  • In ultrasound, the Fraunhofer zone corresponds to which region?
  • What is the frequency range for medical diagnostic Doppler transducers?
  • Lateral resolution is improved by which factors?
  • ______ is the time to complete one cycle.
  • With normal incidence, what factors affect refraction of ultrasound?
  • In ultrasound beam zones, which zone describes the far-field region after the focal point where the beam diverges?
  • What is the primary function of the scan converter in an ultrasound system?
  • Pulse repetition frequency (PRF) is measured in which units?
  • How many bits are needed to represent 32 gray shades?
  • To what factor does a 60 dB increase in output correspond, in terms of times?
  • In a homogeneous medium, if the speed of sound is 1540 m/s and the frequency is 2 MHz, what is the wavelength?
  • Doppler Shifts always occur if the sound source and receiver are in motion.
  • While propagating, a sound wave is refracted. Finally, it returns to the transducer. The system processes the sound wave as if it has:
  • Which component is responsible for converting echo timing into a display image by creating pixels from the received data?
  • Which term describes the fraction of time the machine is emitting a pulse?
  • Among B-mode, gray-scale imaging, continuous-wave Doppler, and pulsed Doppler, which has the greatest output intensity?
  • Which of these intensities is the smallest?
  • Which parameter controls image frame rate in ultrasound systems?
  • Which adjustment is most appropriate when the ultrasound image displays only strong reflectors with little background detail?
  • If an acoustic variable ranges from 55 to 105, what is its amplitude?
  • DICOM is a standard for what in medical imaging?
  • If the frequency of a sound wave is doubled while traveling in the same medium, how is the wavelength affected?
  • What information does Doppler shift provide?
  • Which clinical modality has the lowest output intensity?
  • Regarding dynamic range, increasing it affects grayscale in which way?
  • Which statement describes the effect of increasing transducer diameter on lateral resolution?
  • What is the term for the time from the start of a pulse to its end?
  • Which factor increases patient exposure during an ultrasound exam?
  • Which component is primarily responsible for shaping the transmitted ultrasound beam and coordinating receive timing in an array system?
  • Decimal uses bases of 10; binary uses base 2. Which option lists the base for binary?
  • What is the minimum value of the duty factor?
  • Which change would increase the mechanical index?
  • Rayleigh scattering occurs when scatterers are smaller than wavelength.
  • The more bits per pixel:
  • In the empirical approach, the relationship studied is typically between exposure and response.
  • Harmonics in ultrasound imaging are created primarily in which medium?
  • Impedance is defined as the product of propagation speed and density. Which pair of properties is involved?
  • If the ultrasound instrument's output is increased by 60 dB, the beam intensity increases by approximately how many times?
  • The rayl is the unit of which property?
  • How does speed change when bulk modulus increases?
  • What is the primary purpose of compression in ultrasound imaging?
  • Images on a videotape are stored using which method?
  • As the impedance difference between two media becomes very large, which phenomenon increases?
  • Which statement about wave speed is true?
  • Propagation speed increases most when which combination of material properties occurs?
  • If the lines per frame is increased while the imaging depth remains unchanged, what happens to the frame rate?
  • Which of the following is determined by the source and the medium?
  • Which parameter is determined by the source?
  • Which term describes a transducer containing multiple active elements?
  • What is the primary effect of increasing transmit power on image quality?
  • Enhancement, multipath, and side lobes result in which of the following?
  • All of the following are true of normal cavitation EXCEPT which statement?
  • Which of the following best describes the empirical approach to the study of bioeffects?
  • Which option best describes a sound beam in ultrasound?
  • What can pulsed Doppler measure that continuous wave cannot?
  • The units of attenuation are ___ : this is a ___ scale
  • The ultrasound parameter most closely associated with cavitation risk is
  • Partial volume artifact occurs when echoes from adjacent structures are blended within a single voxel.
  • The maximum frame rate in real-time ultrasound is primarily determined by
  • What is the trade-off of using higher frequency transducers?
  • What is not the responsibility of the sonographer?
  • Which definition correctly describes the period of a wave?
  • Which term describes the display feature that preserves echoes over time, helping visualize motion?
  • A boundary roughness tends to cause which phenomenon?
  • Which statement best describes destructive interference?
  • What is the elimination of voltages that do not exceed a certain level?
  • Which pair best describes the factors that determine the speed of sound in a medium?
  • Which is not a part of the transducer?
  • Doppler spectral aliasing is most likely to occur when:
  • In soft tissue, the attenuation coefficient in dB/cm is approximately equal to one-half of which quantity, expressed in MHz?
  • For a 5 MHz wave, which medium yields the longest wavelength?
  • Which technique improves the signal-to-noise ratio in ultrasound imaging?
  • If the frame rate rises and the lines per frame remain the same, the imaging depth must do what?
  • If the intensity is increased by 3 dB, it:
  • A hydrophone is used to measure which aspect of an ultrasonic signal?
  • The effects of soft tissue on ultrasound are called which property?
  • The consolidation of many images into a single frame best describes which imaging concept?
  • In a real time scanner, which factor determines the maximum frame rate?
  • How does increasing frequency affect attenuation and penetration in soft tissue?
  • In a water tank scan, which region of the sound beam has the highest intensity?
  • Doppler shift is maximal when the flow is parallel to the ultrasound beam.
  • The grainy image texture due to interference of scattered waves is called:
  • A single-element transducer is focused by whom?
  • The Fraunhofer region in ultrasound corresponds to which zone?
  • The Curie Temperature has which effect on the piezoelectric material in ultrasound transducers?
  • What defines spatial pulse length?
  • The duty factor for CW ultrasound is
  • Which instrument is used to measure ultrasound beam intensity?
  • What is the effect of spatial compounding on image quality?
  • With the presence of which phenomenon do we see more boundaries than there are reflecting surfaces?
  • Which is not an acoustic variable?
  • The range equation relates distance from the reflector to which two quantities?
  • The reject control is used to adjust the appearance of which objects?
  • Axial resolution is determined by which parameter?
  • Which action is not typically part of the sonographer's duties?
  • Which change improves lateral resolution by narrowing the beam width?
  • Impedance is the product of ________and ________.
  • Coded excitation is used to improve which aspect of image quality?
  • The accuracy of reflector depth position on an A-mode, B-mode, or M-mode display is called?
  • How many bits are needed to represent 16 shades of grey?
  • If the frequency is decreased, the numerical value of the radial resolution will be:
  • If the frequency is doubled, what happens to the period?
  • If we increase the frequency, the near zone length is:
  • Which boundary produces the strongest reflection?
  • If the frequency is doubled in the same medium, how does the propagation speed change?
  • What is displayed on the x-axis of an M-mode image?
  • If the round-trip time doubles, the reflector distance changes by what factor?
  • Which control is used to compensate for signal loss with depth to keep brightness uniform?
  • Which of the following is not one of the primary attenuation components?
  • Arrange the following media from fastest to slowest propagation speed in a typical medium:
  • What is the fraction of time that a transducer is transmitting?
  • The statement 'A sonographer's education ends when they become registered' is
  • To measure the ultrasound beam intensity, use a
  • The angle between the motion and the ultrasound beam enters into the Doppler shift calculation as which trigonometric function?
  • If wires in an AIUM test object do not appear in the same place as on the display, what is amiss?
  • Which statement about spatial pulse length is true?
  • Which term describes the distance covered by one cycle?
  • Rayleigh scattering in ultrasound occurs when scatterers are much smaller than the wavelength.
  • In a system with a digital scan converter but an analog input signal, which component is required to convert the signal to digital form?
  • Attenuation in soft tissue is closest to:
  • Refraction requires oblique incidence and which condition?
  • If the transducer diameter increases, the lateral resolution at its smallest dimension is:
  • Which statement about ultrasound frequency and resolution is true?
  • A hydrophone is used to measure which property?
  • What determines the propagation speed of ultrasound in a homogeneous medium?
  • A quality assurance program:
  • Which ultrasound system component generates the electrical pulse used to excite the transducer?
  • Which artifact appears most commonly with highly reflective objects?
  • From a safety standpoint, which method is best?
  • Post-processing occurs at which point in the imaging workflow?
  • The speed of sound in soft tissue is closest to which value?
  • Which of the following is associated with cavitation?
  • Coded excitation primarily improves imaging by what mechanism?
  • Which statement describes the duty factor in pulsed ultrasound?
  • If the output of the machine is increased by 20 dB, the beam intensity increases by how much?
  • All of the following are true EXCEPT:
  • In the analog-to-digital converter path, which component stores the image data?
  • Which of the following represents the best lateral resolution?
  • What is the effect of increasing the pulse repetition frequency (PRF) on Doppler measurements?
  • At the focus, the beam diameter is ______ the transducer diameter.
  • Which parameter most directly determines the maximum PRF in ultrasound imaging?
  • Which component is the active element in the transducer?
  • If a 5 MHz wave is traveling in the tissues listed below, which will have the longest wavelength?
  • Cavitation is most likely to occur under which condition?
  • At an air–tissue interface, what fraction of the incident ultrasound energy is reflected?
  • If the patient does not speak English, which action is best to obtain informed consent?
  • Which conversion turns digital signals into analog signals for display in imaging systems?
  • Which statement about exposure to acoustic energy is true?
  • How many bits are needed to represent 1024 gray shades?
  • The dynamic range is the ratio of the smallest to the largest ________ that a system can process without distortion.
  • How many data bits are needed to represent 46 gray shades?
  • Which of the following is a typical unit for amplitude of an ultrasound signal?
  • In which biological tissue will sound travel the fastest?
  • What is the effect of decreasing pulse duration on axial resolution?
  • Which ultrasound safety index gauges heating potential?
  • What happens to venous blood flow to the heart during expiration?
  • The Doppler shift is the _______ of two frequencies.
  • If 300,000 cycles occur in one second, what is the frequency?
  • What is the approximate decibel change when a signal's intensity is reduced to one half?
  • If lines per frame are changed while imaging depth remains constant, what else would change?
  • If a reflector moves twice as far from the transducer, how does that affect the time-of-flight of the sound pulse?
  • In soft tissue, distance traveled is equal to which factor times the round-trip time?
  • A transducer ________ one form of ________ into another.
  • Which unit is used to express volume measurements in ultrasound contexts?
  • The more pixels per inch:
  • An ultrasound system is set to 0db and is transmitting at full intensity. What is the output power when the system is transmitting at 50% of full intensity?
  • Power mode Doppler is typically associated with which characteristics?
  • All of the following will improve temporal resolution EXCEPT:
  • Attenuation coefficient is typically expressed as
  • In a pulsed ultrasound transducer, which factor primarily determines the emitted frequency?
  • A Thermal Index value of 3 implies what potential tissue temperature change?
  • Which has the greatest amount of attenuation?
  • The Doppler shift is a measure of which of the following?
  • The dB is defined as the ______ of two intensities.
  • Dynamic range is defined as the ratio of the smallest to largest amplitude that can be processed without distortion.
  • Which frequency range is typical for Doppler measurements?
  • Snell's law describes the physics of which phenomenon?
  • Which of the following has the greatest influence on temporal resolution?
  • Which device measures the acoustic output of a transducer?
  • True or False: With normal incidence, the angle is 180 degrees.
  • If the frame rate increases and lines per frame are unchanged, what option best describes the change that occurs?
  • Which statement best describes pulse repetition frequency (PRF)?
  • What are the units of intensity?
  • According to AIUM bioeffects, there have been no confirmed bioeffects below intensities of what SPTA?
  • Which boundary will create the strongest reflection?
  • The Nyquist limit in Doppler ultrasound is defined as which of the following?
  • Decibels express the ratio of output quantities on a logarithmic scale. Which option reflects this concept?
  • What is displayed on the y-axis of an M-mode image?
  • Which statement describes the impact of increasing the number of bits per pixel?
  • If the spatial pulse length is 10 mm, what is the axial resolution?
  • Which type of artifact is most closely associated with depth errors caused by incorrect sound speed assumptions?
  • Sound waves are which of the following?
  • Which of the following statements about Doppler frequency shift is true?
  • Which of the following conditions yields the highest mechanical index?
  • Which of the following is NOT used to describe a single ultrasound pulse?
  • What is the standard for communication between medical imaging computers?
  • What artifact has a grainy appearance and is caused by the interference effects of scattered sound?
  • Which artifact is described as a ghosting artifact?
  • Doppler shifts are always created when the source and receiver are in motion relative to each other.
  • If the distance to a target is doubled, the time-of-flight for the pulse round-trip is:
  • Which statement accurately describes the effect of increasing frequency on penetration depth?
  • Which parameter is determined primarily by the medium through which ultrasound propagates?
  • Which pair of medium properties determines the propagation speed of ultrasound?
  • If the frequency is tripled, what happens to the wavelength?
  • Assuming a constant frequency, what happens if the diameter of an unfocused circular transducer is increased?
  • Which quantity does Doppler shift primarily indicate?
  • Doppler shifts depend on which of the following?
  • Can grayscale imaging be adjusted by the sonographer?
  • Dynamic range in ultrasound describes which of the following?
  • Power of sound has units of:
  • Volume has which unit?
  • The region from the transducer to the minimum beam cross-sectional area is known as which zone?
  • What is the location of the minimum cross-sectional area of the beam?
  • Which parameter controls the depth of imaging on the display?
  • The distance over which the ultrasound beam remains relatively narrow and maintains good lateral resolution is called which term?
  • Which factor primarily determines the signal amplitude at the transducer in an ultrasound system?
  • Coded excitation originates from which component of the ultrasound system?
  • If a 5 MHz wave travels through tissues such as fat, air, muscle, and bone, which will have the shortest wavelength?
  • If the angle between the ultrasound pulse and the boundary is 90 degrees, this incidence is called?
  • Which of the following best describes the mechanistic approach to the study of bioeffects?
  • In A-mode ultrasound displays, how is depth represented?
  • Which of the following is ultrasonic and least useful in diagnostic imaging?
  • Which condition improves lateral resolution?
  • The creation of an image by scanning from different angles is best described as what?
  • If output power increases by a factor of 4, how many decibels is this?
  • Sound Intensity decreased by 75% is how decibels of attenuation?
  • The amplitude of a boundary reflection depends on what property of the two media?
  • Which statement is true regarding frequency and penetration?
  • A transducer with more than one active element is called:
  • How is range ambiguity artifact eliminated?
  • Which of the following is proportional to the square of the amplitude?
  • Which material yields the greatest attenuation?
  • Which of the following is not typically a transducer component?
  • Filling in of an anechoic region due to finite slice thickness is known as which artifact?
  • If the wave amplitude doubles, what happens to the acoustic power?
  • What happens to reflections as impedance mismatch between media increases?
  • Which resolution improves most with focusing?
  • Which term describes the redirection of an ultrasound beam in many directions at a rough boundary?
  • Which option best completes the statement: A transducer ________ one form of ________ into another.
  • If frequency increases, the near zone length is:
  • What happens to the speed of sound in a medium when the bulk modulus of the medium decreases?
  • Which Doppler modality is highly sensitive to low-velocity flow but does not provide velocity information?
  • What are the three attenuation components in ultrasound?
  • In real-time ultrasound, the relationship between imaging depth and frame rate is best described as
  • How many decibels are related to a 90% decrease in imaging power?
  • Pre-processing occurs at which stage in ultrasound image formation?
  • Which statement about ultrasound frequency and resolution is true?
  • Which statement best describes a difference between annular and linear phased array transducers?
  • The production of a voltage from deformation is called?
  • If two media share the same propagation speed but have different densities, how does impedance change?
  • If the intensity of a sound beam remains unchanged while the beam area is reduced in half, what has happened to the power?
  • Which is most likely to create Rayleigh Scattering?
  • Time-of-flight in ultrasound refers to what?
  • Which tissue type has propagation speed closest to soft tissue?
  • Which cavitation form is characterized by stable bubble oscillation without collapse?
  • What effect do microbubble contrast agents have on ultrasound images?
  • Rectification and smoothing are associated with which processing stage?
  • In a QA study using a tissue-equivalent phantom, adjusting a brightness control changes reflector brightness from fully bright to barely visible. Which system parameter are you evaluating?
  • The propagation speed of an ultrasound wave is equal to the product of which two quantities?
  • Refraction occurs only if there is which combination?
  • What is a typical Doppler frequency?
  • Multiple reflections that are equally spaced are called:
  • The Fresnel is the:
  • Dynamic range in ultrasound systems is controlled by which control?
  • What is the name of the receiver function that corrects for attenuation?
  • How many centimeters are in 60 millimeters?
  • Which statement accurately describes reverberation artifacts?
  • The production of deformation from voltage is called?
  • If 3 MHz sound has a 2 dB attenuation in 1 cm of tissue, what is the attenuation of 6 MHz sound in 0.5 cm of the same tissue?
  • Which statement describes the effect of increasing pixels per inch?
  • Which cavitation form is associated with shock waves and extreme energy release (violent collapse)?
  • Which factor improves lateral resolution?
  • Which is an advantage of coded excitation in ultrasound imaging?
  • Axial resolution is affected by focusing.
  • What Doppler angle is most inaccurate?
  • Which medium provides the fastest ultrasound propagation speed?
  • Which notation correctly matches mega?
  • If a system is not displaying clear images in the far field, which component is most likely at fault?
  • What is the actual time that an ultrasound machine is creating a pulse?
  • What should you do first when entering a hospital room to perform an ultrasound exam?
  • The following statement is true or false: A mirror image artifact can appear alongside true anatomy.
  • The most likely amount of reflection at a boundary between soft tissue is:
  • The sonographer can influence the duty factor of the ultrasound machine.
  • Impedance is the product of which two tissue properties?
  • Axial resolution is improved by which change?
  • What are the units of longitudinal resolution?
  • PACS primarily provides which function in medical imaging workflows?
  • Which transducer is best suited for imaging superficial structures?
  • The process of reducing the difference between the smallest and largest voltages is called ________.
  • If the bulk modulus increases while density remains constant, the speed of sound will be
  • Which of the following will result in the greatest number of shades of gray in a digital image display?
  • The propagation speed of ultrasound in the AIUM test object is:
  • Changing which of the following would not cause any change in a hard copy image output?
  • Shadowing in ultrasound imaging may occur due to what?
  • Which component in an ultrasound unit contains the memory bank?
  • In ultrasound safety, what does ALARA stand for in practice?
  • If an ultrasound beam strikes a boundary at normal incidence and both media have the same propagation speed, which process cannot occur?
  • Is a sound wave a pressure wave made of compressions and rarefactions?
  • In a B-mode display, which axis is used for the amplitude of the reflection?
  • If the angle between the ultrasound pulse and the boundary is 56 degrees, this incidence is called?
  • Under typical practice, a patient may revoke consent to treatment
  • Which of the following is not a beam steering technique for a mechanical scan head?
  • Put in increasing order of propagation speed
  • Identify one of the advantages of coded excitation.
  • With good images on the display but not on the printer, one should:
  • Which description best characterizes an ideal epidemiological bioeffects study?
  • Which form of cavitation is most likely to produce microstreaming in the intracellular fluid and shear stresses?
  • An ultrasound system is set to 0db and is transmitting at full intensity. What is the output power when the system is transmitting at 10% of full intensity?
Subscribe

Get the latest from Passetra

You can unsubscribe at any time. Read our privacy policy